Research article — evidence review: Off-label use means application outside the FDA-cleared indication. Clinical evidence (RCTs or systematic reviews) supports this use, but the FDA has not cleared it.Article reference: Content describes science, methodology, or organizational reference material — not a clinical efficacy claim.
Evidence: Research reportClinical LiteratureDupuy et al. · Blood vessels, thrombosis & hemostasis, 2025

Abstract

Mouse models, such as the intravital laser-induced model of thrombus formation, are commonly used for mechanistic and preclinical studies in thrombosis. However, their translational value is limited by species differences. Few in vitro models incorporate laser-induced vascular injury. Here, we developed an endothelialized microfluidic device, the Endo-chip, to model thrombus formation in response to laser injury. Citrated blood was treated with IXA4, an endoplasmic reticulum stress inducer, or with antithrombotic agents including antitissue factor antibody (5G9), antiplatelet drugs (abciximab, aspirin), and anticoagulants (argatroban, heparin). Fluorescently labeled antibodies (to platelets, fibrin, or von Willebrand factor [VWF]), annexin V or the calcium dye Cal520, were added to the blood. After recalcification at 10 mM, blood was perfused through the Endo-chip at a shear rate of 100 s-1 or 800 s-1. Endothelial injury was induced with a 355-nm laser pulse producing a focal 10-μm injury, and phosphatidylserine exposure on endothelial cells within ∼1 cell diameter from the injury site. Annexin V-positive endothelial cells expressed tissue factor and released VWF, supporting localized platelet and fibrin deposition. The thrombus formed a teardrop morphology aligned with flow incorporating VWF with increasing shear. IXA4 enhanced platelet cytoplasmic calcium. Platelet accumulation was inhibited by abciximab but not aspirin, whereas coagulation inhibitors (5G9, argatroban, heparin) markedly reduced thrombus formation. These findings support that the Endo-chip laser-injury model incorporates key features of thrombus formation after endothelial injury, and provides a humanized, in vitro, alternative or auxiliary to mouse models for preclinical studies and antithrombotic drug development.

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeJournal Article

Summary

Researchers developed the Endo-chip, an endothelialized microfluidic device in which laser injury triggers thrombus formation in recalcified blood; platelet accumulation was inhibited by abciximab but not aspirin, while anti-tissue factor antibody, argatroban and heparin markedly reduced thrombus growth.

Context

Researchers built the Endo-chip, an endothelialized microfluidic vessel-on-chip that reproduces laser-induced vascular injury and thrombus formation in human blood, and used it to screen antithrombotic agents, showing platelet accumulation was inhibited by abciximab but not aspirin while coagulation inhibitors (anti-tissue-factor 5G9, argatroban, heparin) markedly reduced thrombus formation. This humanized in-vitro platform could, in principle, screen leech-secretome anticoagulant and antiplatelet components in a controlled, species-relevant system, advancing the drug-discovery pipeline beyond mouse models. The study is a preclinical methods/proof-of-concept paper testing reference drugs (no leech-derived compounds), so it demonstrates a tool rather than any clinical antithrombotic effect.

Citation

Reference (Vancouver style)

Dupuy A, Qi M, Fenwick JCL, Yates DM, Coleman PR, Gamble JR, et al. Endo-chip laser-induced thrombus formation: a vessel-on-chip model for in vitro testing of antithrombotic agents. Blood Vessel Thromb Hemost. 2025;2(4):100096. doi:10.1016/j.bvth.2025.100096. PMID: 41030610

Bibliographic details (authors, volume, pages, DOI) are taken from the PubMed record.

Added to ASH library: May 28, 2026 · Site last updated: November 1, 2026

This website provides educational information and does not constitute medical advice, diagnosis, or treatment recommendations. Medicinal leech therapy carries clinically meaningful risks and should be performed only by qualified clinicians under institutionally approved protocols. FDA 510(k) clearance for medicinal leeches is limited to specific indications; investigational and off-label discussions are labeled accordingly. For patient-specific guidance, consult a qualified healthcare provider.