American Society of Hirudotherapy

Is colour Doppler ultrasound a sensitive screening method in diagnosing deep vein thrombosis after hip surgery?

Comparative study published in Thromb Haemost (1996)

Last Updated: November 1, 2026ASH Editorial · based on the books
Research article — evidence review: Off-label use means application outside the FDA-cleared indication. Clinical evidence (RCTs or systematic reviews) supports this use, but the FDA has not cleared it.Article reference: Content describes science, methodology, or organizational reference material — not a clinical efficacy claim.
Evidence: Observational studySalivary PharmacologyDrug DevelopmentMagnusson M et al. · Thromb Haemost, 1996

Abstract

Patients under going orthopedic surgery are at high risk of developing deep vein thrombosis. One hundred and thirty-eight consecutive patients undergoing total hip replacement or hip fracture surgery were included in this study. They were surveilled with colour Doppler ultrasound (CDU) and bilateral ascending contrast phlebography. The prevalence of proximal and distal DVT in this study was 5.8% and 20.3% respectively. CDU has a satisfactory sensitivity in patients with symptomatic deep vein thrombosis, especially in the proximal region. These results could not be confirmed in the present study of asymptomatic patients. The sensitivity was 62.5% (95% confidence interval: C.I. 24-91%) and the specificity 99.6% (C.I. 98-100%) for proximal DVT; 53.6% (C.I. 34-73%) and 98% (C.I. 96-99%) respectively for distal thrombi. the overall sensitivity was 58.1% (C.I. 39-75%) and the specificity 98% (C.I. 96-99%). The positive predictive value was 83.3% (C.I. 36-99%) and 75% (C.I. 51-91%) for proximal and distal DVT respectively. The negative predictive value was 98.9% (C.I. 98-100%) and 94.9% (C.I. 92-98%) for proximal and distal DVT respectively. The results of this study showed that even with a highly specialised and experienced investigator the sensitivity of CDU was too low to make it suitable for screening purposes in a high risk surgical population.

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeComparative StudyJournal Article
Indexed MeSH termsAnticoagulantsDalteparinDextransHip FracturesHip ProsthesisHirudin TherapyHirudinsHumansIncidencePhlebographyPostoperative CarePostoperative ComplicationsPredictive Value of TestsRecombinant ProteinsRiskSensitivity and SpecificityThrombophlebitisUltrasonography, Doppler, Color

Summary

In 138 patients undergoing total hip replacement or hip fracture surgery, colour Doppler ultrasound showed overall sensitivity of 58.1% and specificity of 98% against phlebography for DVT, too low for screening asymptomatic high-risk surgical patients.

Context

This study evaluated color Doppler ultrasound (CDU) as a screening tool for deep vein thrombosis in 138 consecutive patients undergoing total hip replacement or hip fracture surgery, comparing it with bilateral ascending contrast phlebography. It reported overall sensitivity of 58.1% and specificity of 98%, concluding that CDU sensitivity was too low for screening in this high-risk surgical population. The study concerns diagnostic imaging after hip surgery and does not investigate hirudotherapy, the leech secretome, or any anticoagulant intervention. No leech-related findings, conclusions, or agents are discussed in the abstract.

Citation

Reference (Vancouver style)

Magnusson M, Eriksson BI, Kälebo P, Sivertsson R. Is colour Doppler ultrasound a sensitive screening method in diagnosing deep vein thrombosis after hip surgery? Thromb Haemost. 1996;75(2):242-245. PMID: 8815568

Bibliographic details (authors, volume, pages, DOI) are taken from the PubMed record.

Added to ASH library: May 27, 2026 · Site last updated: November 1, 2026

This website provides educational information and does not constitute medical advice, diagnosis, or treatment recommendations. Medicinal leech therapy carries clinically meaningful risks and should be performed only by qualified clinicians under institutionally approved protocols. FDA 510(k) clearance for medicinal leeches is limited to specific indications; investigational and off-label discussions are labeled accordingly. For patient-specific guidance, consult a qualified healthcare provider.