Research article — evidence review: Off-label use means application outside the FDA-cleared indication. Clinical evidence (RCTs or systematic reviews) supports this use, but the FDA has not cleared it.Article reference: Content describes science, methodology, or organizational reference material — not a clinical efficacy claim.
Evidence: Research reportClinical LiteratureSafety & Infection ControlWood E et al. · The Annals of pharmacotherapy, 2020

Abstract

BACKGROUND: Impella devices offer temporary mechanical circulatory support for cardiogenic shock. The manufacturer recommends systemic anticoagulation with a target activated clotting time of 160 to 180 s but provides no guidance on how to manage both the heparinized purge solution and the additional intravenous heparin needed to reach this therapeutic range. Previous publications demonstrated a lack of standardization in heparin management for Impella devices. OBJECTIVE: The purpose of this study was to compare the effectiveness and safety of 2 different heparin protocols for long-term Impella support. METHODS: This single-center, retrospective study included adult patients on Impella support for greater than 24 hours. The primary end point was time to therapeutic range measured in hours, from time of implantation to the first of 2 consecutive measurements within the therapeutic range. Secondary end points included percentage of time in therapeutic range, rates of major bleeding, pump thrombosis, hemolysis, and nursing satisfaction. RESULTS: There were 19 patients identified, with 7 using the original protocol and 12 using the revised protocol. Time to therapeutic range was similar between protocols (15.5 vs 12 hours, P = NS). Another 14 patients were managed with patient-specific protocols as a result of bleeding or physician preference. In total, 42% of all patients in this study experienced major bleeding. There were no confirmed thrombosis events. This study was limited by a small sample size. CONCLUSION AND RELEVANCE: Despite using different heparin protocols, outcomes and bleeding events were similar between groups. Future studies are needed to determine the optimal degree of anticoagulation necessary to reduce bleeding risk.

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeJournal Article
Indexed MeSH termsAdultAnticoagulantsBlood CoagulationCohort StudiesFemaleHeart VentriclesHeart-Assist DevicesHemorrhageHeparinHumansMaleMiddle AgedRetrospective StudiesShock, CardiogenicThrombosisTreatment Outcome

Summary

This single-center retrospective study of Impella-supported adults (19 on two standardized heparin protocols, 14 on patient-specific regimens) found similar time to therapeutic range (15.5 vs 12 hours) between protocols; no confirmed pump thrombosis occurred, but 42% of all patients experienced major bleeding.

Context

This single-center retrospective study compared two heparin protocols for anticoagulating patients on Impella percutaneous ventricular assist devices, finding similar time-to-therapeutic-range between protocols and no confirmed thrombosis events, but a notably high major-bleeding rate (42% of all patients), and concluding that the optimal degree of anticoagulation to reduce bleeding remains undefined. It documents how difficult precise anticoagulation control is even with heparin in a closely monitored device setting — the kind of unmet need that sustains interest in alternative, more predictable antithrombotic mechanisms such as the direct thrombin-inhibiting peptides characterized in the medicinal-leech secretome. Honest caveat: this is a small (19-patient) retrospective single-center cohort with no leech-therapy content whatsoever; its findings are hypothesis-generating only.

Citation

Reference (Vancouver style)

Wood E, Hayes C, Hart A. Anticoagulation Management for Impella Percutaneous Ventricular Assist Devices: An Analysis of a Single-Center Experience. Ann Pharmacother. 2020;54(11):1073-1082. doi:10.1177/1060028020922542. PMID: 32410456

Bibliographic details (authors, volume, pages, DOI) are taken from the PubMed record.

Added to ASH library: May 28, 2026 · Site last updated: November 1, 2026

This website provides educational information and does not constitute medical advice, diagnosis, or treatment recommendations. Medicinal leech therapy carries clinically meaningful risks and should be performed only by qualified clinicians under institutionally approved protocols. FDA 510(k) clearance for medicinal leeches is limited to specific indications; investigational and off-label discussions are labeled accordingly. For patient-specific guidance, consult a qualified healthcare provider.